![J. C. Meyer Solvent Drying System](/media/2159/solvent_drying_system.jpg)
J. C. Meyer Solvent Drying System
Our chemistry lab has a J. C. Meyer solvent drying system. This system provides a safe and reliable source of anhydrous solvents for sensitive reactions. Currently this system is set up for six common solvents: tetrahydrofuran (THF), diethyl ether (Et2O), dichloromethane (CH2Cl2), toluene (PhCH3), acetonitrile (CH3CN), and dimethylformamide (DMF).
![Buchi Rotavapor R-215](/media/2157/rotavapor.jpg)
Buchi Rotavapor R-215
Buchi R-215 Rotavapor unit in the chemistry lab is used to evaporate solvents. Each unit is coupled with a single Buchi V-700 self-clean pump and a Buchi B-491 Heating Bath. Rotavapor R-215 can rotate samples between 25–4000 mL at a rate of 20–280 rpm with maximum flask weight of 3 kg. Currently our lab has three Buchi R-215 rotavapors.
![Buchi V-700 pump](/media/2151/buchi.jpg)
Buchi V-700 pump
Buchi V-700 pump has an ultimate vacuum (absolute) rating of < 10 mbar and an ultimate vacuum rating of 24 mbar when using a gas ballast.
Buchi B-491 Heating Bath
This heat bath accompanying the rotavapor unit has a temperature range between 20–180 ± 2 °C and a bath size of 4 L.
Thermo Scientific Immersion Coolers
Neslab CC 100 allows for cooling to a temperature of -90 ± 0.5° C. The immersion coolers allow our laboratory to function continuously even when lacking a supply of dry ice.
![Sanplatec Dry Keeper Cabinet Desiccator](/media/2158/sanplatec.jpg)
Sanplatec Dry Keeper Cabinet Desiccator
This sanplatec cabinet desiccator is used to store moisture sensitive reagents.
![Binder FD 240 Drying Ovens](/media/2152/drying_ovens.jpg)
Binder FD 240 Drying Ovens
Two Binder Ovens are set up for drying glassware.
![Buchi Melting/Boiling Point M-560](/media/2155/melting_point.jpg)
Buchi Melting/Boiling Point M-560
Buchi M-560 is used to determine either melting or boiling point of a newly synthesized compound. Three different samples can be determined simultaneously. Buchi M-560 easily records the melting-point/boiling-point temperature range, only by pressing one button twice.
![Fume Hoods](/media/2153/fume_hoods.jpg)
Fume Hoods
Our laboratory has eight functional fume hoods and one solvent hood. Fume hoods are fully supplied with natural gas, pressured air, high-purity nitrogen, and DI water. Fume hood is also equipped with monkey bars to easily set up reactions, and a horizontal/vertical combo sash. Both the solvent hood and horizontal/vertical combo sash are designed to ensure work safety.
![Laboratory](/media/2154/lab.jpg)
![Mettler Toledo XS204 Delta Range Analytic Balance](/media/2150/analytic_balance.jpg)
Mettler Toledo XS204 Delta Range Analytic Balance
This analytic balance is routinely used the chemical weighting purpose. Its maximum weight capability is 220 g and weight accuracy of 0.1 mg. The balance uses a "SmartGrid" rather than traditional weighing system. The SmartGrid is used to weight samples in testing tubes and round-bottom flasks. It reduces possible turbulence from air or sample left on the balance that may lead to inaccuracy in measurement.
More details at: www.mt.com
![Mettler Toledo MS3002S Precision Balance](/media/2156/precision_balance.jpg)
Mettler Toledo MS3002S Precision Balance
This top-loading balance offers a maximum weight capability of 3200 g and weight accuracy of 0.01 g.